What are the key differences in charge transport behavior between quasi-hemispherical and coplanar-grid CdZnTe detectors?

Blog / Date: January 4, 2026 / Author: CdZnTe.com / Hits: 17

## Overview of Quasi-Hemispherical and Coplanar-Grid CdZnTe Detectors


CdZnTe (CZT) detectors are widely used for gamma-ray spectroscopy due to their room-temperature operation and good energy resolution. Among the various electrode configurations developed to improve charge collection and spectral quality, quasi-hemispherical and coplanar-grid designs represent two important and distinct approaches. Both aim to mitigate the effects of hole trapping and improve charge transport efficiency, but they differ fundamentally in their electrode geometry, charge sensing mechanisms, and charge transport behavior.

## Electrode Geometry and Configuration


In a quasi-hemispherical CZT detector, the electrode arrangement consists of a small hemispherical anode placed on one face of a relatively large-volume CZT crystal, with the cathode covering the opposite face. The small anode radius concentrates the electric field lines into a quasi-spherical region near the anode, creating a strongly non-uniform electric field within the crystal volume.

In contrast, the coplanar-grid detector uses two interleaved comb-shaped anode electrodes patterned on one surface of the crystal, with a single cathode on the opposite side. These two grids are biased with slightly different voltages, enabling differential charge collection. The electric field within the bulk is more uniform compared to quasi-hemispherical detectors but is shaped by the grid geometry near the anode surface.

## Charge Collection Mechanism and Weighting Potential


The quasi-hemispherical design relies on the weighting potential focusing near the small anode. This strong weighting potential gradient ensures that the detector signal is primarily sensitive to the motion of electrons close to the anode, reducing sensitivity to holes and their trapping.

Charge carriers generated throughout the detector volume drift under the influence of the electric field. Due to the field shape, electrons drift relatively directly toward the small anode, while holes move toward the large cathode. The strong field near the anode enhances electron collection efficiency and suppresses hole signal contributions.

For coplanar-grid detectors, the two interleaved anode grids produce distinct weighting potentials. By taking the difference of signals induced on the two grids, the detector effectively isolates the electron contribution while canceling out hole-induced signals, because holes induce nearly equal signals on both grids.

This differential measurement compensates for hole trapping and improves energy resolution by effectively ignoring the less mobile and more trapping-prone holes. The weighting potential distribution in the coplanar-grid configuration is designed to be sensitive to electron motion in the bulk, with signal induction occurring primarily near the anode grids.

## Electric Field Distribution and Carrier Drift Paths


In quasi-hemispherical detectors, the electric field is highly non-uniform, with a strong field concentration near the small anode. This results in relatively long electron drift paths through low-field regions before entering the high-field region near the anode, where charge collection is rapid. Holes drift in the opposite direction toward the cathode, experiencing more uniform fields but significant trapping risk due to longer transit times.

In coplanar-grid detectors, the electric field inside the bulk is designed to be more uniform to ensure consistent electron drift velocities throughout the volume. Near the anode surface, the field is shaped by the grid geometry, directing electrons toward the collecting grid. This more uniform field profile reduces carrier trapping compared to non-uniform fields and improves the overall charge collection.

## Sensitivity to Hole Trapping


Both detector types aim to minimize the adverse effects of hole trapping, but they do so by different mechanisms. The quasi-hemispherical design minimizes hole signal contribution by geometry-induced weighting potential focusing, so that holes contribute little to the output signal, reducing spectral tailing caused by hole trapping.

Coplanar-grid detectors actively subtract the signals induced on two grids to eliminate hole contributions electronically. This method effectively cancels the hole signals and compensates for depth-dependent charge loss due to hole trapping, resulting in improved spectral peak shapes and energy resolution.

## Signal Formation and Pulse Shapes


In quasi-hemispherical detectors, the signal formation is dominated by electron motion near the small anode, leading to characteristic pulse shapes with a rapid rise once electrons enter the high-field region. Pulse shape variations can be more pronounced due to the non-uniform field and varying electron drift times from different interaction depths.

Coplanar-grid detectors produce signals based on the difference between two grid signals, which tends to yield more uniform pulse shapes because the detector response is largely independent of interaction depth. This enables better pulse shape consistency and facilitates pulse shape discrimination techniques.

## Complexity and Fabrication Considerations


Quasi-hemispherical detectors have a relatively simple electrode structure, requiring only a small anode and a cathode, simplifying fabrication and assembly. However, their non-uniform field may require careful biasing and optimization to balance charge collection efficiency and leakage currents.

Coplanar-grid detectors require precise lithographic patterning of interleaved anode grids and control of bias voltages to maintain differential signal extraction. This complexity increases fabrication challenges but enables enhanced performance by electronically compensating for hole trapping effects.

## Performance and Application Differences


Quasi-hemispherical detectors are often favored for large-volume detectors where simple electrode geometry and moderate performance are acceptable. They provide reasonable energy resolution and are robust against hole trapping due to weighting potential focusing.

Coplanar-grid detectors are widely used when high spectral resolution and minimal low-energy tailing are critical, especially in applications demanding precise energy discrimination. Their electronic hole compensation yields superior energy resolution and better spectral peak shapes.

## Summary


The key differences in charge transport behavior between quasi-hemispherical and coplanar-grid CdZnTe detectors stem from their electrode geometries and charge sensing methods. Quasi-hemispherical detectors utilize a small anode to create a non-uniform electric field and weighting potential that focuses on electron collection, reducing hole contributions by design. Coplanar-grid detectors employ interleaved anode grids with differential readout to electronically cancel hole signals and enhance electron charge collection uniformity. These fundamental differences affect electric field distributions, carrier drift paths, sensitivity to hole trapping, signal formation, and ultimately detector performance and application suitability.



CdZnTe Association (CdZnTe.com)
https://www.cdznte.com/blog/what-are-the-key-differences-in-charge-transport-behavior-between-quasi-hemispherical-and-coplanar-grid-cdznte-detectors.html
CZT Detectors
Collection of a curated range of high-performance cadmium zinc telluride (CZT) radiation detectors for medical, security, and scientific applications
CZT Detector Bare Die for Gamma Ray
CZT Detector Bare Die for Gamma Ray
MFG: Prosun Semiconductor
Hits: 290
CZT Detector Bare Die for X Ray
CZT Detector Bare Die for X Ray
MFG: Prosun Semiconductor
Hits: 7438
CZT Substrate for HgCdTe-Based Infrared Detection
CZT Substrate for HgCdTe-Based Infrared Detection
MFG: Prosun Semiconductor
Hits: 181
GalaxRay RIID high-resolution CZT-based Personal Radiation Device
GalaxRay RIID high-resolution CZT-based Personal Radiation Device
MFG: NUVIATech Instruments
Hits: 35
NuVISION-MAX CZT-based high performance gamma imager
NuVISION-MAX CZT-based high performance gamma imager
MFG: NUVIATech Instruments
Hits: 46
NuVISION compact portable spectrometric gamma camera based on CZT
NuVISION compact portable spectrometric gamma camera based on CZT
MFG: NUVIATech Instruments
Hits: 42